Contact Us
- 2F. No.216-2, Zhongzheng Rd., Shulin Dist., New Taipei City 238, Taiwan
- fong.yong01@msa.hinet.net
- +886-2-26824939

High-Strength Clear Casting Epoxy for River Tables | EC-165 / HC-191
EC-165/HC-191 is a 3:1 clear casting epoxy with 14,000 psi flexural strength, Shore D 80, and 12% elongation for shaded indoor river tables and long-span castings.
Description
Fong Yong Chemical Co., Ltd. is one of the leading manufacturers and suppliers of high-strength clear casting epoxy for river tables | ec-165 / hc-191 in Taiwan. With abundant experience, we warmly welcome you to buy high quality customized products at competitive price from our factory. If you have any enquiry about quotation, please feel free to email us.
EC-165 / HC-191 is the high-strength clear casting system for large-slab river tables, long-span table surfaces, and mechanically demanding indoor castings where flexural performance is the primary design requirement. At 14,000 psi flexural strength and 12% elongation, it is built for the load geometry that large-format river tables actually experience - wide epoxy channels spanning long unsupported sections under daily use.
A casting that cures water-white may still be an incorrect specification if flexural performance is not evaluated alongside appearance. For large-slab river tables and long-span structural castings, transparency is one part of the requirement - the other is whether the cured resin can accommodate bending load across an unsupported span under normal indoor service conditions.
Common Questions Before Ordering
Will it crack in use?
EC-165 / HC-191 is formulated for large-format river tables where the epoxy fill spans a wide unsupported section under daily load. At 14,000 psi flexural strength and 12% elongation, it is specified when bending stress across a wide river channel must be considered under normal indoor service conditions. Note: EC-165 / HC-191 is a standard formula - it will yellow under sustained window UV-A. For window-lit rooms, evaluate E-1006T / HC-191 instead.
How thick can I pour per layer?
A conservative field guideline is 20–25 mm per pour at 25°C. Higher ambient temperature or larger casting mass requires shallower layers. A 10 cm deep river channel requires a minimum of 4–5 separate pours - each layer should reach surface gel stage (tacky, no longer liquid) before the next pour is added. Validate on a test geometry before committing to production pours.
How hard does it cure?
Shore D 80 - a firm, hard surface suitable for large dining tables, conference tables, and commercial counters in shaded indoor environments. For river table specification, hardness should be reviewed together with flexural strength, elongation, span length, river-channel width, and installation environment.
Actual Customer Project - Large River Table with Wide Epoxy Channel
F
Figure 1. Actual Customer Project - Large River Table with Wide Epoxy Channel | Cast with EC-165 / HC-191
Large River Table with Wide Epoxy Channel
Cast with EC-165 / HC-191.
Project details are unavailable because the table was produced and supplied through an independent distributor.
The project shown above illustrates the type of application where casting geometry, river channel width, and long-span structural performance become important specification criteria.
EC-165 / HC-191 is commonly selected for large river tables installed in shaded indoor environments where mechanical performance matters as much as appearance.
Important: exact table length, river width, and casting thickness are not stated because those dimensions were not recorded. This protects B2B credibility and avoids publishing unverified numeric claims.
Not Sure Whether EC-165 / HC-191 Is the Right Specification?
Material selection based solely on appearance can result in choosing the wrong casting system for a large river table.
Before casting, send us:
- Table length
- Table width
- River channel width
- Installation environment
Our technical team can help determine whether EC-165 / HC-191 is appropriate before production begins.
What EC-165 / HC-191 Is Designed For
EC-165 / HC-191 solves the mechanical failure mode of large-slab river tables: resin fill that cannot flex enough across a wide, unsupported span. With 14,000 psi flexural strength and 12% elongation, it is the system specified when the table geometry demands structural performance, not just water-white appearance.
- Flexural strength 14,000 psi: relevant for large-slab river tables and long-span table surfaces where the epoxy section carries bending load across unsupported geometry.
- Elongation 12%: higher toughness under impact and load than harder, less flexible systems.
- Shore D 80: hard cured surface suitable for daily-use table and counter applications in shaded indoor environments.
- UV note: standard formula - suitable for shaded indoor environments. Not formulated for anti-yellowing performance under window light.
- Product fit: large river tables, long-span conference tables, shaded commercial counters, and indoor castings where flexural performance matters more than UV appearance retention.
| Mix Ratio | 3:1 (EC-165 Resin : HC-191 Hardener) by weight | Shore D | 80 |
| Flexural Strength | 14,000 psi | Elongation | 12% |
| Pot Life | ~60 minutes at 25°C | UV Rating | Standard - shaded indoor environments |
Primary applications: Large-slab river tables in shaded interiors · Long-span conference and reception tables · Shaded commercial counters · Clear structural castings where flexural strength is the primary design criterion
Where EC-165 / HC-191 Is Specified

Figure 2. EC-165 / HC-191 is specified for large river tables, long-span indoor tables, and large structural clear castings where flexural strength and toughness are the primary performance criteria.
EC-165 / HC-191 is specified when casting geometry creates structural demand. The best EC-165 / HC-191 applications are projects where span length, epoxy-channel width, load distribution, and low-UV indoor installation conditions make flexural performance the primary selection criterion.
Primary Applications
- Large-slab river tables in shaded interior spaces - basements, north-facing rooms, windowless commercial environments
- Long-span commercial counters in shaded interiors - corridor counters, interior hotel bars, and reception tables where the epoxy section carries daily-use load away from direct window light
- Large transparent structural castings - clear cast components where geometry, span, or embed configuration creates mechanical demand during service
- Structural clear casting applications where flexural load across an unsupported span is a design consideration
- Large clear architectural castings - transparent indoor casting blocks or panels where mechanical integrity is more important than appearance alone
Industrial and workshop clear casting where water-white transparent appearance is required and flexural integrity is a design criterion, but UV stability is not the primary requirement
Secondary Applications - Validate by Environment
- South-facing or window-lit room river tables: EC-165 / HC-191 may yellow under sustained window UV-A. Evaluate E-1006T / HC-191 if the table will be in a brightly lit interior.
- Commercial counters in naturally lit spaces: where window exposure is significant, an appearance-retention formula should be evaluated before specification. See UV environment boundary below.
When High Flexural Strength Matters
Flexural strength becomes increasingly important as casting geometry becomes larger and the epoxy section carries more load across an unsupported span.
- Large river tables
- Wide epoxy channels
- Long unsupported spans
- Commercial tables under daily use
- Large reception and conference tables
In these applications, mechanical performance becomes an important part of material selection rather than appearance alone.
Why Flexural Strength Determines River Table Performance
Large river tables sometimes develop hairline cracks along the wood-resin boundary - not because the bond between resin and timber fails, but because the resin fill cannot flex enough across a long unsupported span under daily load. EC-165 / HC-191 addresses this specific failure mode. At 14,000 psi flexural strength and 12% elongation, it carries the bending load a large-slab river table actually experiences without transmitting stress to the boundary.
Flexural strength is the material property that resists bending across an unsupported span. A river table is a structural panel: a large live-edge timber slab with an epoxy fill spanning between two support points. When the table is used daily - dining weight, shifting, cleaning - the epoxy fill is under continuous flexural stress at that span. The formula that cures water-clear on day one must also hold that geometry under load across years of service.
For a river table with a 1.5-metre epoxy channel across a 2.4-metre span, this difference is not academic. A table that shows hairline cracking along the wood-resin boundary over months of normal use is often the result of a formula with insufficient flexural strength for the geometry and loading conditions - not a failure of adhesion or mixing technique.

Figure 3. Flexural strength determines how a cured epoxy fill resists bending across an unsupported span. At 14,000 psi, EC-165 / HC-191 carries the load a large-slab river table experiences in daily use. The difference between a formula at 14,000 psi and one at 4,800 psi is visible over time - in hairline cracking along the wood-resin boundary under cumulative load.
When Flexural Strength Is the Primary Criterion
- Wide epoxy channels spanning a significant portion of the table length
- Long unsupported spans between table legs or supports
- Heavy daily use - dining tables, commercial bar counters
- Live-edge slabs with irregular wood-resin boundaries that create stress concentrations
Where these conditions exist and the UV environment is shaded, EC-165 / HC-191 is the mechanically appropriate specification. For installations where both structural demands and UV exposure are high, see the UV environment boundary section below.
Formula Characteristics and What the Spec Data Shows
EC-165 / HC-191 uses HC-191 hardener at a 3:1 mix ratio by weight. HC-191 is a water-white clear hardener used across Fong Yong's clear casting range - the mixing process, pot life, and handling procedure are consistent across systems that use it.
The mechanical profile of EC-165 / HC-191 reflects a formula optimised for structural performance. Shore D 80 provides a hard cured surface. The 14,000 psi flexural strength is the standout figure for large-slab applications. The 12% elongation - substantially higher than harder, more brittle formulas - means the cured system absorbs impact and load variation without cracking rather than resisting it rigidly.
The tensile strength of 7,200 psi and compressive strength of 5,800 psi are in line with a standard structural clear casting system. EC-165 / HC-191 is specified for mechanical performance in shaded indoor environments - the UV environment boundary and appropriate installation profiles are covered in the section below.
UV Environment and Where EC-165 / HC-191 Works Best
The UV environment of the installation is the first variable in formula selection. EC-165 / HC-191 performs well in shaded indoor spaces. In window-lit rooms or under continuous display lighting, the standard formula will yellow over time - the rate and visibility depend on UV intensity, substrate colour, and daily exposure duration.
Environment-to-Formula Matching
| Installation Environment | EC-165 / HC-191 | Note |
|---|---|---|
| Basement or interior room - no direct window light | Suitable | Standard formula appropriate for low-UV environments |
| North-facing interior - diffuse light, minimal UV | Suitable | Lower UV-A exposure than window-lit environments. Yellowing may still occur depending on cumulative exposure duration and substrate colour. |
| South- or east-facing windows - natural daylight | Evaluate alternative | Window UV-A sufficient to drive visible yellowing depending on UV intensity and substrate colour. Consider E-1006T / HC-191 if appearance retention is required. |
| Window-lit counter or surface under sustained LED or fluorescent lighting | Evaluate alternative | Continuous artificial UV accumulates over service life. Discuss with customer before specifying. |
| Outdoor or direct sun exposure | Not suitable | Neither standard nor anti-yellowing indoor formula is rated for direct outdoor UV. Consult Fong Yong. |
The yellowing limitation of EC-165 / HC-191 is not a reason to exclude it from the catalogue - it is a reason to specify it correctly. A shaded basement river table finished with EC-165 / HC-191 will perform reliably for its service life. The same table placed beside south-facing windows requires a different formula at the specification stage, or a client conversation about appearance expectations before the project starts.

Figure 4. EC-165 / HC-191 is a standard clear casting formula - rated for shaded indoor environments. Where the installation will be in a window-lit room or under sustained display lighting, an anti-yellowing formula should be evaluated. This is a specification decision, not a product limitation.
Application Fit and Boundaries
EC-165 / HC-191 should be treated as a mechanically proven clear casting resin for shaded indoor environments. The product role is clear: it is the high-flexural, high-elongation choice when the installation environment does not require an anti-yellowing formula.
Primary Fit
- Large-slab river tables in basements, north-facing rooms, or other shaded interiors
- Long-span commercial counters in shaded environments - interior corridors, hotel bars, windowless dining spaces, and reception tables away from direct window light
- Large transparent structural castings - clear cast components where mechanical integrity and water-white appearance are required and UV exposure is low
- Large-format clear castings and structural resin sections where flexural performance is a design criterion
Other Structural Casting Applications
- Large-format structural castings requiring high flexural strength - where span, geometry, or embedded hardware creates internal stress during service
- Transparent structural castings where mass, span, or differential cure contraction places mechanical demand on the cured resin beyond what display-optimized formulas are designed for
- Industrial clear casting blocks, clear fixtures, and transparent structural castings where mechanical durability is the primary criterion and the installation environment is shaded
- Large clear cast components where mechanical integrity over service life matters more than long-term UV appearance retention
Secondary Fit - Discuss Before Specifying
- River tables in rooms with south- or east-facing windows - yellowing risk should be discussed with the end customer
- Commercial counters with display lighting - UV accumulation may produce visible yellowing depending on fixture type, intensity, and substrate colour
Not the Primary Specification
- Window-lit indoor surfaces where appearance retention is the priority: specify E-1006T / HC-191 instead.
- Anti-yellowing projects of any type: EC-165 / HC-191 is a standard formula and should not be positioned as anti-yellowing.
- Outdoor installations: neither standard nor anti-yellowing indoor formula is rated for outdoor UV and weathering. Consult Fong Yong for appropriate outdoor systems.
Common Questions
When is EC-165 / HC-191 not the right choice?
If the installation is window-lit - south- or east-facing rooms, surfaces under sustained display lighting - a standard formula will yellow over time and an appearance-retention formula should be evaluated instead. EC-165 / HC-191 is the right specification when the UV environment is shaded and the casting geometry creates structural demand. When the UV environment is the primary concern rather than mechanical performance, a different product in the Fong Yong range is the appropriate specification.
Not the Right Fit for Your Project?
Both EC-165 / HC-191 and E-1006T / HC-191 use the same HC-191 hardener at a 3:1 mix ratio - the working process is identical. The selection between them is driven by the UV environment and the structural demands of the application. If the installation is window-lit and appearance retention over service life is the priority, E-1006T / HC-191 is the appropriate specification.
Discuss Your River Table Project
Every river table has different geometry, span length, installation conditions, and appearance requirements.
Before selecting a casting system, send us:
- Table dimensions
- River channel dimensions
- Installation environment
- Expected service conditions
Our technical team can help determine whether EC-165 / HC-191 is the correct specification for your project before production begins.
Request River Table Review → Technical Consultation →
If appearance retention under window UV is the primary requirement, →see E-1006T / HC-191 - the indoor appearance-retention specification for window-lit environments.
Hot Tags: high-strength clear casting epoxy for river tables | ec-165 / hc-191, suppliers, manufacturers, factory, customized, Self Leveling Clear Doming Epoxy Resin, Hard Clear Epoxy for Carbon Fiberglass, Clear Epoxy, UV Resistant Clear Epoxy Resin, Clear Flexible Sticker Doming Epoxy Resin, Clear Epoxy for Making River Table
Technical Specifications - EC-165 / HC-191
| Property | EC-165 (Part A) | HC-191 (Hardener) |
|---|---|---|
| Appearance | Clear liquid | Clear liquid |
| Viscosity (cps, 25°C) | 1,000 – 4,000 | 100 – 200 |
| Mix Ratio (by weight) | 3 : 1 (EC-165 : HC-191) | |
| Pot Life / Working Time | ~60 min at 25°C | |
| Initial Cure Time | RT: 12–24 hours or 80°C × 1–2 hours (varies by section size) Note: Gel time indicates full gelation of the mass - not the inter-layer timing for layer casting. For layer pouring, the next pour is added when the surface is no longer liquid and is tacky to the touch, but not yet hard. See preparation guidelines below. |
|
| Full Cure Time | 7 days at room temperature or 80°C × 2 hours |
|
| Hardness (Shore D) | 80 | |
| Flexural Strength (psi) | 14,000 | |
| Tensile Strength (psi) | 7,200 | |
| Compressive Strength (psi) | 5,800 | |
| Elongation (%) | 12 | |
| UV Resistance | Standard - shaded indoor environments Not formulated for anti-yellowing performance. Will yellow under sustained window UV-A or display lighting. |
|
| Cure Conditions | Room temperature or elevated temperature (80°C) | |
| Substrate Compatibility | Commonly used on: Wood, timber slabs, stone, ceramic, metal, glass Not compatible: PP, PE, PC, PVC, Teflon, silicone (standard epoxy limitation; specialized treatment required) |
|
Data from Fong Yong laboratory experiments under controlled conditions. Working time, gel time, and cure conditions vary with batch volume, ambient temperature, and section geometry. Test before production use.
Preparation and Application
- Use a clean, dry container and mixing rod. Contamination from moisture or previous mixes affects cure.
- Weigh EC-165 (Part A) and HC-191 (Hardener) at a 3:1 ratio by weight. Accurate weighing is critical - ratio errors affect mechanical properties and cure completeness.
- Mix thoroughly. Scrape the container walls and bottom. Unmixed material at the edges will remain tacky in the finished casting.
- For large castings or water-white appearance-critical applications, vacuum degassing the mixed resin (10 min) prior to pouring removes entrained air bubbles.
**Layer pouring guideline - 20–25 mm per pour at 25°C.
For EC-165 / HC-191, thick sections should be poured in layers because pot life, gel time, and cure behaviour vary with resin mass, section thickness, mold geometry, and ambient temperature. A conservative field guideline is 20–25 mm per pour at 25°C. Higher ambient temperature, lower mold heat dissipation, or larger casting mass should use shallower layers. Deep castings - such as river table channels - therefore require multiple sequential pours: a 10 cm channel requires a minimum of 4–5 separate pours. Each layer should reach surface gel stage before the next pour is added - the surface is no longer liquid and is tacky to the touch, but not yet hard. Pouring at this stage helps promote interlayer bonding and reduces the risk of visible layer lines. Waiting until the layer is fully cured before adding the next pour may produce a visible layer line unless the cured surface is sanded, cleaned, and reactivated before the next pour. The recommended layer thickness should be validated on a representative casting geometry - matching the actual section size, mold material, and ambient conditions - before committing to production pours.
Pour gently to avoid trapping air in the stream.
Cure per the conditions above. Full mechanical properties develop over 7 days at room temperature.
You Might Also Like










