-
Phone
+886-2-26824939
-
Address
2F. No.216-2, Zhongzheng Rd., Shulin Dist., New Taipei City 238, Taiwan
-
E-mail
Is E-120/H-100 Suitable For Wire Coil And Transformer Potting?
E-120/H-100 is specified for coil winding and transformer potting applications where cracking under reeling stress is a concern. Shore D 82 hardness, 13,000 psi flexural strength, RT cure without heat equipment. Here is what to evaluate before specifying it for your coil application.What Substrates Does E-120/H-100 Bond To, And What Adhesion Data Is Available?
E-120/H-100 bonds to aluminum, iron, and other common electronic assembly substrates. Published lap shear data: aluminum 650 psi, iron 1,010 psi, sanded iron 2,500 psi. Here is what these figures mean for potting and bonding applications.Why Does E-120/H-100 Have Higher Flexural Strength Than Other Clear Epoxy Potting Compounds?
E-120/H-100 delivers 13,000 psi flexural strength — the highest in Fong Yong's clear electronic potting range. Here is what that means for coil winding, wire reeling, and applications where cracking resistance after cure matters.How Does The Low Exothermic Reaction in E-120/H-100 Protect Electronic Components During Potting?
E-120/H-100 generates low exothermic heat during the curing process — a design feature that protects sensitive electronic components from thermal stress during potting. Here is how exotherm affects potted assemblies and why it matters.Can E-120/H-100 Reach Full Mechanical Performance Without Heat Curing?
E-120/H-100 cures fully at room temperature over 7 days, reaching Shore D 82 and 13,000 psi flexural strength without a heat curing step. Here is what the RT cure schedule delivers and when heat cure is worth adding.Why Do Two Epoxy Tables From The Same Formula Look Different After Extended Indoor Use? SEO Metadata
A common source of confusion: two tables cast from the same formula, even from the same batch, show noticeably different appearances after extended indoor use. One is still clear. The other has developed an amber tint. The formula was not different. The mixing was done the same way. The difference was created by where each table was placed — and that difference in placement determined the UV-A dose each table received over its service life.Will A Clear Epoxy Table in A Shaded Room Still Yellow Over Time?
Placing a clear epoxy table in a room without direct sunlight is the most common approach to reducing UV exposure. It works — but the reduction in UV-A is not always as complete as assumed. A room described as "shaded" can still deliver a real UV-A dose to a table through reflected light, seasonal sun angle changes, and incidental window exposure at certain times of day. What matters is the actual UV-A reaching the table surface, not the general description of the room.Why Does The Wood-Resin Boundary Crack After The Table Has Been in Use?
A common report from river table owners: everything looked perfect at completion, but after some time in use, a hairline has appeared along one or both sides where the wood meets the epoxy. The table was not dropped. Nothing visible happened. The crack was not there during the first inspection. This is not a workmanship failure that appeared late. It is a stress accumulation problem — one that develops gradually under cyclic loading that is invisible until it crosses a visible threshold.